Ilmi, Bahrul (2014) Prototype pendeteksi dan penetralisir kebocoran LPG otomatis menggunakan metode fuzzy logic. Undergraduate thesis, Universitas Islam Negeri Maulana Malik Ibrahim.
|
Text (Fulltext)
07650017.pdf - Accepted Version Available under License Creative Commons Attribution Non-commercial No Derivatives. Download (2MB) | Preview |
Abstract
INDONESIA:
Penggunaan tabung LPG yang semakin meluas di Indonesia memiliki efek yang sangat berbahaya jika penggunaan tidak sesuai prosedur, dan tabung LPG menyita korban dari tahun-ketahun. Hal ini terjadi akibat gas propana dan metana yang terdapat di dalam tabung LPG mudah terbakar. Jika tabung LPG atau perangkat lainya mengalami kebocoran dan LPG mengendap pada lantai dapur maka dalam jumlah tertentu LPG akan bereaksi terhadap api, dan mengakibatkan kebakaran.
Dengan menggunakan metode Fuzzy Logic, prototype akan lebih efisien dalam menetralisir kebocoran LPG pada ruangan dengan cara mengeluarkan kandungan LPG yang mengendap pada ruangan demgam menggunakan kipas DC yang di atur kecepatannya (PWM) sesuai dengan aturan fuzzy. Ketika ada kebocoran, kedua sensor MQ5 dan LM35 akan membaca kondisi ruangan yang berukuran 30x30x15 cm. MQ5 akan membaca jumlah kebocoran LPG (ppm), dan jika kebocoran lebih dari 1000 ppm maka buzzer akan buerbunyi untuk memberikan signal peringatan dan kipas akan berputar sesuai dengan hasil input sensor MQ5 (LPG) dan LM35 (suhu), kombinasi input kedua tersebut akan diproses melalui ADC Atmega 8535.
Tingkat keberhasilan dari prototype ini mencapai 86% untuk mendeteksi dan menetralisir kebocoran LPG, dengan adanya prototype ini diharapkan akan memudahkan peneliti selanjutkan untuk menerapkan sistem yang lebih komplek pada ruangan dapur tidak hanya pada prototype.
ENGLISH:
The use of LPG cylinders are increasingly widespread in Indonesia have a very harmful effect if the use is not in accordance with procedures, and LPG cylinders seized victims year after year. This occurs as a result of propane and methane gas contained in flammable LPG cylinders. If the LPG cylinders or other devices and LPG leak settles on the kitchen floor in a certain amount of LPG will react to fire, and cause fire.
By using the fuzzy logic method, a prototype will be more efficient in neutralizing LPG leakage in the room by removing the content of LPG which settles in the room to make use of the regulated DC fan speed (PWM) according to the fuzzy rules. When there is a leak, both MQ5 and LM35 sensor will read room conditions measuring 30x30x15 cm. MQ5 will read the amount of leakage of LPG (ppm), and if the leak is more than 1000 ppm, the buzzer will sound to provide warning signals and the fan will rotate according to the results of sensory input MQ5 (LPG) and LM35 (temperature), the input combination of the two will be processed on Atmega8535 ADC.
The success rate of this prototype was 86% to detect and neutralize leakage of LPG, with the prototype is expected to facilitate further research to implement a more complex system in the room the kitchen is not only the prototype.
Item Type: | Thesis (Undergraduate) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Supervisor: | Arif, Yunifa Miftachul and Nugroho, Fresy | |||||||||
Contributors: |
|
|||||||||
Keywords: | LPG; Pendeteksi dan Penetralisir; Fuzzy; PWM; Prototype; Detector and Neutralizer | |||||||||
Departement: | Fakultas Sains dan Teknologi > Jurusan Teknik Informatika | |||||||||
Depositing User: | Desi Latifah Hamzah | |||||||||
Date Deposited: | 14 Aug 2017 15:40 | |||||||||
Last Modified: | 14 Aug 2017 15:40 | |||||||||
URI: | http://etheses.uin-malang.ac.id/id/eprint/7733 |
Downloads
Downloads per month over past year
Actions (login required)
View Item |