Pendugaan Reservoar Sistem Panas Bumi menggunakan Metode Geolistrik Dipole-Dipole: Studi kasus Sumber Air Panas Daerah Lombang, Sumenep Madura

Arfiyaningsih, Sofi (2015) Pendugaan Reservoar Sistem Panas Bumi menggunakan Metode Geolistrik Dipole-Dipole: Studi kasus Sumber Air Panas Daerah Lombang, Sumenep Madura. Undergraduate thesis, Universitas Islam Negeri Maulana Malik Ibrahim.

[img] Text (Fulltext)
10640065.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (3MB) | Request a copy

Abstract

ABSTRAK

Telah dilakukan penelitian dengan menggunakan Metode geolistrik resistivitas konfigurasi dipole-dipole di daerah sumber air panas daerah Lombang Kecamatan Batang-Batang Kabupaten Sumenep dengan tujuan untuk mengetahui model aliran panas bumi yang terdapat pada area penelitian dan untuk mengetahui karakteristik struktur bawah permukaan di area penelitian dengan menggunakan metode geolistrik tahanan jenis dipole-dipole. Data yang diukur ialah nilai beda potensial (V) dan kuat arus (I) sehingga diketahui nilai resistivitasnya. Dari nilai resistivitas tersebut kemudian dihitung nilai resistivitas semunya. Kemudian data tersebut dijadikan sebagai data masukan ke software res2dinv untuk dibuat pemodelan penampang 2D. Dari pemodelan tersebut dapat teridentifikasi jenis litologi bawah permukaan daerah penelitian. Penelitian ini mengambil data dari 3 lintasan dengan 2 lintasan sejajar dan 1 lintasan memotong kedua lintasan sejajar tersebut. Hasil pengukuran menunjukkan bahwa pada lintasan 1 nilai resistivitas yang terukur berada dalam rentang 292-10658.06 ohm meter. Pada lintasan 2 nilai resistivitas yang terukur dalam rentang 45,3-11784 ohm meter. Sedangkan pada lintasan 3 nilai resistivitasnya berada dalam rentang 0,994-7202 ohm meter. Kedalaman hasil pemodelan mencapai 40m untuk lintasan 1 dan 2 dan 60m untuk lintasan 3.

ABSTRACT

Has done research with using electrical resistivity methods with dipole-dipole configuration in the Lombang hot springs area, Batang-batang district Sumenep with the aim to know a model of the flow of heat the earth that there are in the area of research and to know the structure characteristic of below the surface in the area of research using a method of geolistrik dipole-dipole kind of prisoners. Measured the data is the value of the potential difference (V) and current (I) so its value of resistivity be known. The value of resistivity then is calculated the value of resistivity everything was .Then the data used as input data into software res2dinv to be made of modeling a cross section 2D. From that modeling can be identified a kind of lithology below the surface of the research area.This study took a line data from 3 with 2 the line of parallel to and 1 line of cutting two parallel line both. The result of measurement shows that the value of resistivity be measurable at line 1 in range 292-10658.06 ohm meters. On the line 2 the value of resistivity be measurable within the span 45.3-11784 ohm meters. While in the line 3 value of resistivity be measurable in range 0,994-7202 ohm meters. The depth of the results of modeling at up to 40 m to line of 1 and 2 and 60 m to the line of 3.

Item Type: Thesis (Undergraduate)
Supervisor: Basid, Abdul and Tirono, Mokhamad
Contributors:
ContributionNameEmail
UNSPECIFIEDBasid, AbdulUNSPECIFIED
UNSPECIFIEDTirono, MokhamadUNSPECIFIED
Keywords: Sistem Panas Bumi; Geolistrik; Dipole-dipole Geothermal System; Electrical Resistivity; Dipole-dipole