Responsive Banner

Pemanfaatan Port Serial PC untuk pembuatan RLC Meter

Viyanto, Ratna Ari (2014) Pemanfaatan Port Serial PC untuk pembuatan RLC Meter. Undergraduate thesis, Universitas Islam Negeri Maulana Malik Ibrahim.

[img] Text (Fulltext)
09640032.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (2MB) | Request a copy

Abstract

ABSTRAK

Tujuan penelitian ini adalah: Merancang alat ukur RLC meter berbasis Port Serial PC sebagai alat pendukung. Membuat dan mengimplementasikan alat ukur RLC meter pada PC. Metode penelitian dilakukan dengan pendekatan secara deskripif yaitu membandingan hasil kalibrasi dengan variasi resitor dan capasitor dan dibandingkan dengan hasil yang diperoleh pada alat yang dibuat.

Hasil yang diperoleh dari penelitian ini yaitu telah dirancang bangun sebuah alat RLC meter dengan memanfaatkan port serial PC yang telah dimodivikasi dengan menampilkan keluaran berupa grafik diolah melalui softwere Visual Basic. Analisa data yang di peroleh dalam alat ini, dibandingkan dengan hasil kalibrasi dan di masukkan kedalam rumus, didapatkan kesalahan relatif pada alat. Kesalahan relatif pada alat dan hasil kalibrasi berbeda. Pada saat pengambilan data, data yang diperoleh berubah-ubah untuk satu sampel. Hal ini disebabkan karena pada alat ini tidak mengunakan komponen yang memiliki kualitas sedang. Dan juga terdapat komponen-komponen liar pada rangkaian.

ABSTRACT

The purpose of this research is: designing the RLC meter gauge Serial Port-based PC as a means of support. Create and mengim plementasikan RLC meter gauge on the PC. The research method is done with a deskripif approach that compares the results of calibration with variations resitor and capasitor and compared with the results obtained on the tool created.

The results from this research that have been designed a tool RLC meter by utilizing the PC serial port that has been with the modified form of graphs showing the output is processed through Visual Basic softwere. Analysis of the data obtained in this tool, compared with the calibration results and insert into the formula, the relative error obtained on the tool. The relative error on the tool and the calibration results are different. At the time taking of data, it obtained change for one sample. This is because the tool is not using components that have medium quality. And there are also wild components in the circuit.

Item Type: Thesis (Undergraduate)
Supervisor: Hananto, Farid Samsu and Abidin, Munirul
Contributors:
ContributionNameEmail
UNSPECIFIEDHananto, Farid SamsuUNSPECIFIED
UNSPECIFIEDAbidin, MunirulUNSPECIFIED
Keywords: Port Serial PC; RLC Meter; Visual Basic 6.0 Port Serial PC; RLC Meter; Visual Basic 6.0
Departement: Fakultas Sains dan Teknologi > Jurusan Fisika
Depositing User: Moch. Nanda Indra Lexmana
Date Deposited: 03 May 2023 14:14
Last Modified: 03 May 2023 14:14
URI: http://etheses.uin-malang.ac.id/id/eprint/49319

Downloads

Downloads per month over past year

Actions (login required)

View Item View Item